DIFFERENTIAL
PRESSURE AND LEVEL TRANSMITTERS:
|
|
TPR-14/N
|
|
Data
Sheet.pdf |
|
|
Silicon
sensor with ceramic substrate pressure transmitter. Ranges from 250mbar
to 10 bar and -1 to 0 bar, 0.5% accuracy. Pneumatic and vacuum applications. |
|
|
TPR-14
/LP../HP |
|
Data
Sheet.pdf |
|
|
Ceramic
sensor pressure transmitter. Range up to 400 bar, 0.5% accuracy. General
applications for Gas and Liquids.
|
|
TPR-18 |
|
Data
SheeT.pdf
|
|
|
Ceramic
sensor pressure transmitter. Range up to 600 bar, 0.2% accuracy. General
applications for Gas and Liquids.
|
|
|
TPR-16 |
|
Data
Sheet.pdf
|
|
|
Silicon
sensor with ceramic substrate pressure transmitter. Ranges up to 1000
mbar, 0.5% accuracy. Low pressure applications for non-aggressive
fluids in vacuum, medicine, investigation, etc. |
|
TPR-21 |
|
Data
Sheet.pdf |
|
|
Ceramic
sensor pressure transmitter. Range up to 400 bar, 0.5% accuracy. Applications
for viscous, pasty, aggresive and contaminated media, etc. |
|
|
TPR-22 |
|
Data
Sheet.pdf |
|
|
Stainless
Steel sensor pressure transmitter. Range up to 2200 bar, 0.25% accuracy.
For very high pressure applications, machine tools, hydraulic presses,
Test stands, etc. |
|
DIFFERENTIAL
PRESSURE |
TPD-1100 |
|
Data
Sheet.pdf |
|
|
Piezoresistive
sensor differential pressure transmitter. Range from 6 mbar up to
1000 mbar, 0.5% accuracy. Low gauge or differential pressure applications,
filter monitoring, HVAC, clean rooms, medical equipment, flow velocity,
etc.
|
|
|
TPD-1300 |
|
Data Sheet.pdf |
|
|
Inductive
sensor pressure transmitter. Range from 0.1 up to 1000 mbar, 0.5%
accuracy. Very Low gauge or differential pressure applications, filter
monitoring, HVAC, clean rooms, medical equipment, flow velocity, etc. |
|
TPD-18 |
|
Data
Sheet.pdf
|
|
|
Stainless
Steel sensor pressure transmitter. Range up to 16 bar, 0.5% accuracy.
Flow control, filter monitoring and general differential pressure
applications. |
|
|
|
FLUSH
DIAPHRAGM LEVEL TRANSMITTERS |
TPM-18 |
|
Data
Sheet.pdf |
|
|
Stainless
Steel flush diaphragm pressure transmitter. Range up to 400 bar, 0.5%
accuracy. Process control applications, chemical industry, foodstuff
industry, paper industry, pharmaceutical industry, etc. |
|
|
TPM-30 |
|
Data
Sheet.pdf |
|
|
Stainless
Steel flush diaphragm pressure transmitter. Range up to 400 bar, 0.25%
accuracy. Process control applications, chemical industry, foodstuff
industry, paper industry, pharmaceutical industry, DN or Clamp process
connection. Special execution for high temperature up to 300ºC
as an option. |
|
TPM-40 |
|
Data
Sheet.pdf
|
|
|
Stainless
Steel sanitary flush diaphragm pressure transmitter. Range up to 400
bar, 0.25% accuracy. Provide 3 functions in one: Pressure transmitter,
presostate and digital indicator in the field. Process control applications
in chemical industry, foodstuff industry, pharmaceutical industry,
DN or Clamp process connection. Special execution for high temperature
up to 300ºC as an option. |
|
|
|
NIVEL
HIDROSTÁTICO |
TNE-12/LL../HL |
|
Data
Sheet.pdf
|
|
|
Stainless
Steel flush diaphragm level transmitter. Range up to 400 mH2O, 0.25%
accuracy. Tank level measurement of of neutral and aggressive fluids
in chemical and pharmaceutical industries, foodstuff industry, galvanic
industry, water treatment, etc. |
|
|
TNE-12/T |
|
Data
Sheet.pdf
|
|
|
Ceramic
capacitive sensor level transmitter. Range up to 10 mH2O, 0.25% accuracy.
Tank level measurement for aggresive liquids in chemical and pharmaceutical
industries, medical equipment, water treatment, etc. |
|
TNE-16 |
|
Data
Sheet.pdf
|
|
|
Ceramic
capacitive sensor flush diaphragm level transmitter. Range up to 200
mH2O, 0.25% accuracy. Tank level measurement for liquids starting
at 600mmH2O in chemical and pharmaceutical industries, foodstuff industry,
water treatment, etc. |
|
|
|
SUBMERSIBLE
LEVEL TRANSMITTER |
TNS-119 |
|
Data
Sheet.pdf |
|
|
Stainless
Steel sensor and body submersible level transmitter. Range up to 160
mH2O, 0.25% accuracy. 19mm Diameter. Typical applications level measurement
in wells, tanks, of fluids compatibel with Stainless steel. For pipes
of 22mm diameter and up. |
|
|
TNS-127 |
|
Data
Sheet.pdf |
|
|
Stainless
Steel sensor and body submersible level transmitter. Range up to
160 mH2O, 0.25% accuracy. 27mm Diameter. Typical applications level
measurement in wells, tanks, of fluids compatibel with Stainless
steel.
|
|
TNS-200 |
|
Data
Sheet .pdf
|
|
|
Stainless
Steel sensor submersible level transmitter, body in PVC. Range up
to 100 mH2O, 0.25% accuracy. 35mm Diameter. Typical applications level
measurement in wells, tanks, of fluids compatibel with Stainless steel
and PVC |
|
|
TNS-227
TNS-237 |
|
Data
Sheet .pdf
|
|
|
Stainless
Steel body and ceramic sensor submersible level transmitter. Range
up to 160 mH2O, 0.5% accuracy. 27 or 37 mm Diameter. Typical applications
level measurement in wells, tanks, etc. |
|
TNS-300 |
|
Data
Sheet.pdf |
|
|
Stainless
Steel body and ceramic capacitive sensor submersible level transmitter.
Range up to 200 mH2O, 0.25% accuracy. 45 mm Diameter. Typical applications
level measurement in aggressive media such as acid, bleach, chemical
and pharmaceutical industries, galvanic industry, etc.
|
|
|
TNS-240 |
|
Data
Sheet.pdf |
|
|
Stainless
Steel body and ceramic capacitive sensor submersible level transmitter.
Range up to 200 mH2O, 0.25% accuracy. 39.5 mm Diameter. Typical applications
level measurement in open tanks from 600mmH2O of aggressive fluids
in chemical and pharmaceutical industries, galvanic industry, water
treatment, and viscous media such as slurries, etc. |
|
TNS-400 |
|
Data
Sheet.pdf
|
|
|
Stainless
Steel or CuNiFe alloy body and ceramic capacitive sensor submersible
level transmitter, mounting flane (optional). Range up to 200 mH2O,
0.25% accuracy.Specially designed for hydrostatic level measurement
for navigation and offshore applications, ballast containers, fuel
and oil tanks, service and waste water, etc. |
|
|
|